CFLTH - 00706 P.D.R.P., LUBRICANTS, RUST (SUP DAT)
- MSDS: CFLTH
- Manufacturer: SPRAYON PRODUCTS
- Product Name: 00706 P.D.R.P., LUBRICANTS, RUST (SUP DAT)
- National Stock Number: 9150-00N078240
Product Identification
Product ID:00706 P.D.R.P., LUBRICANTS, RUST (SUP DAT)
MSDS Date:05/17/1993
FSC:9150
NIIN:00N078240
MSDS Number: CFLTH
Responsible Party
SOLON, OH 44139
US
Emergency Phone: 216-292-7400
Info Phone: 800-777-2966
Cage: 09800
Contractor
Telephone: 216-292-7400 OR 216-595-8634
Cage: 09800
Ingredients
1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE;
CAS: 76-13-1
RTECS: KJ4000000
Fraction By Weight: 47%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM/1250 STEL
ALKYLATE PETROLEUM DISTILLATES; (ALIPHATIC HC DISTILLATE)
CAS: 64741-73-7
Fraction By Weight: 25%
OSHA PEL 100 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
760.0
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: 8%
OSHA PEL 5000 PPM
ACGIH TLV: 5000 PPM/30000 STEL
BARIUM (SARA 313)
CAS: 7440-39-3
RTECS: CQ8370000
Fraction By Weight: 20%
OSHA PEL 0.5 MG/M3
ACGIH TLV: N/K
VOC AS PERCENT BY WEIGHT EXCLUDING FEDERALLY EXEMPT
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
RTECS: 9999999ZZ
HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
RTECS: 9999999ZZ
NO SMOKING IN AREA OF USE. DO NOT USE IN THE
RTECS: 9999999ZZ
SURFACES. HEAT AND/OR UV RADIATION MAY CAUSE THE
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRIT OF EYES, SKIN & RESP SYS.
MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON &
POSS DEATH. SIGNS & SYMPS OF OVEREXP: EXCESS EXPOS TO VAPS/SPRAY
MISTS MAY CAUSE HDCH, DIZZ, NAUS & LOSS OF COORD. EXCESS SKIN &
EYE EXPOS MAY CAUSE REDNESS & ITCH/BURNING SENSATION. CHRONIC:
PRLNG (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:OVEREXP TO SOLV INGS MAY CAUSE ADVERSE
EFTS TO LIVER, URINARY, BLOOD-FORMING, CARDIOVASCULAR & REPRO SYS.
RPTS HAVE ASSOC RPTD & PRLNG OVEREXP TO SOLVS W/PERM BRAIN & NERV
SYS DMG. CHLOROFLUO ROCARBON MATLS HAVE PRDCED SENSIT OF MYOCARDIUM
TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN
HUMANS.(ING 6)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
First Aid
First Aid:INHAL: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE. EYES: FLUSH W/LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.
INGEST: NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO
NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. SEEK MEDICAL
ATTENTION.
Fire Fighting
Flash Point Method:PMCC
Flash Point:>200F,>93C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP . WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG
NOZ ARE PREF. WATER MAY BE USED TO (SUP DAT)
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE DUE TO THE
BUILD-UP OF PRESSURE WHEN EXPOSED TO EXTREME HEAT. THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND PHOSGENE .
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:CONTENTS UNDER PRESSURE. DO NOT
PUNCTURE, INCINERATE OR EXPOSURE TO TEMPERATURE ABOVE 120F. DO NOT
TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN.
Other Precautions:HEAT FROM SUNLIGHT, RADIATORS, STOVES, HOT WATER, &
OTHER HEAT SOURCES COULD CAUSE CONTR TO BURST. INTENTIONAL MISUSE
BY DELIBERATELY CONC & INHALING CONTENTS CAN BE HARMFUL/FATAL. USE
ONLY W/ADEQ VEN T. AVOID BRTHG VAP & SPRAY MIST. (ING 8)
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED ORGANIC
VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH FOR PROTECTION.
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS IS MAINTAINED
< APPLIC EXPOS LIM. REFER TO OSHA STDS 1910.91, (SUP DAT)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING. AVOID CONTACT WITH SKIN
AND EYES.
Supplemental Safety and Health
TRADE NAME/PART #: PREVENTATIVES & MAINTENANCE PRODUCTS-1. FIRE FIGHT
PROC: COOL CLSD CONTRS TO PVNT PRESS BUILD-UP & POSS
AUTOIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. VENT: 1910.107,
1910.108.
Chemical Properties
Boiling Pt:B.P. Text:>176F,>80C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:>25
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE, OXIDES OF METALS LISTED IN INGREDIENT SECTION. HCL,
PHOSGENE .
Disposal
Waste Disposal Methods:WASTE FROM THESE PRODUCTS MAY BE HAZARDOUS AS
DEFINED UNDER RCRA 40 CFR 261. DO NOT INCINERATE. DEPRESSURIZE
CONTAINER. DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE & LOCAL
REGULATIONS REGARDING POLLU TION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.